Format |
|
Last Updated |
| Policies, Specifications, etc. |
Minimum Standards for the Design & Construction
of Water and Sanitary Sewer Systems
(This file may take several moments to download.)
|
PDF |
4 MB |
7/2/08 - Effective immediately, American AVK fire hydrants are no longer approved for use
12/6/07 - minor changes
11/1/07 -View summary of revisions (PDF)
7/27/07 - New policies for installation of dedicated fire services.
|
Development Information Guide
|
PDF |
260 KB |
|
| Developer Policies |
PDF |
260 KB |
5/30/08 Clarified W88005 (Installation of Fire Hydrants).
04/30/08 Updated policy WS2006001 (Water & Wastewater Maintenance Bonds)
|
| List of area fire departments |
PDF |
15 KB |
|
| List of Approved Contractors |
HTML |
- |
6/17/08 |
| Grease Trap and Grease Interceptor Standards |
PDF |
450 KB |
9/10/07- made available on web |
| Backflow requirements |
HTML |
- |
|
Water and sewer connection fees
(tap and impact fees) |
HTML |
- |
7/27/07- Connection fees eliminated for dedicated fire service connections. View press release. |
| Account origination and other fees |
HTML |
- |
|
| Water and sewer rates |
HTML |
- |
Rate increase effective 12/01/2007 |
| Application for temporary use of fire hydrants |
Fillable PDF form |
450 KB |
Click here for hydrant use rates, effective 1/1/08. |
| |
|
|
|
| Forms |
| Service Availability Request Form |
Fillable PDF form |
|
5/30/07- Now a fillable PDF form! |
| Hydrostatic Flow Test Request Form |
Fillable PDF form |
95 KB |
|
SCDHEC Potable Water Systems
Construction Permit Application |
Fillable PDF form |
335 KB |
|
| Application for Service |
Fillable PDF form |
420 KB |
7/18/08 |
| Grease Trap Application |
Fillable PDF form |
35 KB |
9/10/07- Now a fillable PDF form! |
| |
|
|
|
| Standard Construction Details |
Below is a list of Charleston Water's Construction Details, grouped by water and sewer. Each drawing is available in AutoCAD or Adobe PDF format; simply click the appropriate link to download in the desired format.
Note: If the file does not automatically open in AutoCAD when you click the link, right-click on the link and select "Save Target As," then save the file to your computer and open in AutoCAD. |
Water System Construction Details |
Notes:
All Charleston Water System drawings were revised in November 2007. Please download the updated versions!
|
No. |
Description |
Format |
Last Updated |
| 1 |
Water Main Bedding
|
|
|
11/07 |
| 2 |
Typical Road Cut
|
|
|
11/07 |
| 3 |
Main Under Paved Driveway
|
|
|
11/07 |
| 4 |
Restrained Joint Fitting
|
|
|
11/07 |
| 5 |
Bell Joint Clamp
|
|
|
11/07 |
| 6 |
Vertical Offset
|
|
|
11/07 |
| 7 |
Typical Hydrant
|
|
|
11/07 |
| 8 |
Typical Tapping Sleeve
|
|
|
11/07 |
| 9 |
Typical Unmetered Fire Service
|
|
|
new 11/07 |
| 10 |
Valve Box
|
|
|
11/07 |
| 11 |
Precast Concrete Collar
|
|
|
11/07 |
| 12 |
Tracer Wire Detail for Plastic Water Piping
|
|
|
11/07 |
| 13 |
Intersection Valve Location
|
|
|
11/07 |
| 14 |
Dead End Blowoff for 4 inch Main
|
|
|
11/07 |
| 15 |
Temporary Blowoff
|
|
|
11/07 |
| 16 |
Typical Air Release Valve Manhole
|
|
|
11/07 |
| 17 |
Air Release Valve
|
|
|
11/07 |
| 18 |
Pipe and Casing Jack and Bore
|
|
|
11/07 |
| 19 |
¾” to 1” Near Side Water Service
|
|
|
11/07 |
| 20 |
¾” to 1” Far Side Water Service
|
|
|
11/07 |
| 21 |
2” Water Service
|
|
|
11/07 |
| 22 |
Typical 1” Double Water Service
|
|
|
11/07 |
| 23 |
Typical Water Service Location
|
|
|
11/07 |
| 24 |
3” Compound Meter with Bypass
|
|
|
11/07 |
| 25 |
4” to 10” Meters with Bypass
|
|
|
11/07 |
| 26 |
Precast Vaults
|
|
|
11/07 |
| 27 |
Typical 15’ CPW Water Easement
|
|
|
11/07 |
| 28 |
Typical Valve Card
|
|
|
11/07 |
| 29 |
Charleston Water System Valve Marker
|
|
|
11/07 |
| 30 |
No file for this number
|
|
|
|
| 31 |
Typical DCVA 2” and Smaller
|
|
|
11/07 |
| 32 |
Typical DCVA Larger than 2”
|
|
|
11/07 |
| 33 |
Typical RPPA (All Sizes)
|
|
|
11/07 |
| 34 |
Typical RPPA (All Sizes) with Enclosure
|
|
|
11/07 |
| 35 |
Typical PVB ½” through 2”
|
|
|
11/07 |
| 36 |
Meter and Backflow Schematic
|
|
|
11/07 |
| 37 |
Water System Notes |
|
|
11/07 |
| |
|
|
|
|
Sanitary Sewer System Construction Details
|
Notes:
All Charleston Water System drawings were revised in November 2007. Please download the updated versions!
|
No. |
Description |
Format |
Last Updated |
| 41 |
Minimum Bedding for Gravity Sewer Line
|
|
|
11/07 |
| 42 |
Typical Sewer Main Road Cut
|
|
|
11/07 |
| 43 |
Sewer Main Under Paved Driveway
|
|
|
11/07 |
| 44 |
Sewer Main Crossing Water Line
|
|
|
11/07 |
| 45 |
Crossing Under Storm Drain Line
|
|
|
11/07 |
| 46 |
Concrete Encased Pipe
|
|
|
11/07 |
| 47 |
Eccentric Cone Precast Manhole
|
|
|
11/07 |
| 48 |
Precast Shallow Manhole
|
|
|
11/07 |
| 49 |
Inside Drop Manhole
|
|
|
11/07 |
| 50 |
Doghouse Manhole on PVC
|
|
|
11/07 |
| 51 |
Doghouse Manhole on Clay Pipe
|
|
|
11/07 |
| 52 |
Typical Standard Manhole Plan
|
|
|
11/07 |
| 53 |
Manhole Inverts
|
|
|
11/07 |
| 54 |
Sewer Service and Cleanout
|
|
|
11/07 |
| 55 |
Sewer Service with Elder Valve
|
|
|
11/07 |
| 56 |
Sewer Service Connection to Main
|
|
|
11/07 |
| 57 |
Deep Sewer Service Connection
|
|
|
11/07 |
| 58 |
Pump Station with Above Ground Piping
|
|
|
11/07 |
| 59 |
Typical Duplex Grinder Pump Station
|
|
|
new 11/07 |
| 60 |
Pump Station Electrical Schematic Under 20hp
|
|
|
11/07 |
| 61 |
Submersible Pump Station Typical Site Plan
|
|
|
11/07 |
| 62 |
Typical Fence Line Span
|
|
|
11/07 |
| 63 |
Pump Station Vehicle Gate
|
|
|
11/07 |
| 64 |
Pump Station Sign
|
|
|
11/07 |
| 65 |
Transducer Mounting Plate
|
|
|
11/07 |
| 66 |
Tracer Wire and Magnetic Tape for Force Mains
|
|
|
11/07 |
| 67 |
Force Main Tie-In at Manhole
|
|
|
11/07 |
| 68 |
Force Main Isolation Pit
|
|
|
new 11/07 |
| 69 |
Air Release Valve and Vault
|
|
|
11/07 |
| 70 |
1000 Gallon Grease Trap |
|
|
11/07 |
| 71 |
1500 Gallon Grease Trap |
|
|
11/07 |
| 72 |
Pipe and Casing Jack and Bore |
|
|
11/07 |
| 73 |
Wastewater System Notes |
|
|
1/08 |
| 74 |
Typical Grinder Station Service Connection |
|
|
11/07 |